Metal Pipe, Rotameter, Variable-area Flowmeter

DescriptionValue
Measuring rangeWater:1-200000L/H(20°C)
Air: 0.03~6000m3/h (20°C, 0.1013MPa)
Measuring range proportionStandard: 10:1; Special: 20:1
Accuracy classStandard:1.5; Special: 1.0
Pressure classStandard:DN15~DN50≤4.0MPa;
High pressure:DN15~DN50≤
Pressure loss7Kpa-70kpa
Medium TemperatureStandard:-40°C~+100°C; PTFE:-50°C~+100°C
High pressure:110°C~+450°C
Medium viscosityDN15:Ƞ<5mPa.s(F15.1~F15.3),
Ƞ<30mPa.s(F15.4~F15.8) DN25:Ƞ<250mPa.s; DN50~DN200:Ƞ<300mPa.s
Environment temperatureRemote type: -40°C~+85°C
On-the spot needle indicator: -40°C~+100°C
Connection typeStandard: DIN2501 standard flange; special: customize
Wiring connectionM20×1.5 female thread
(1/2NPT female thread for Exd explosion-
Power supplyproof) Standard: 24VDC two-line
4~20mA(12VDC~32VDC) Warning type:24VDC four-line
4~20mA(18VDC~18VDC) AC type:85~265VAC 50HZ
Battery type:3.6V 7.5AH lithium battery(3 years lifetime)
Loading resistance featureTwo-line: max loading resistance=50×(voltage-12)Ω=600Ω 24V
Multi-line: max loading resistance 500Ω
Warning signal outputReed pipe warning switch output, upper limit and lower limit flow warning(contact capacity 1A 30VDC)
Electric relay output(contact capacity 1A
Pulse output30VDC, 0.25A 250VAC,0.5A 125VAC) Min space 50ms
LCD display(max loading 100mA 30VDC, internal Instantaneous flow display scope:0~50000
Total flow display scope: 0~99999999
Protection gradeIP65
Explosion-proof gradeExia II CT5Ga Exd II BT6Gb

Please call us @ +1-213-798-0903 or email: contact@igeus.biz for price.